Level 1 sweep and inspection to the NFPA 211 annual standard - flue, crown, cap, and flashing checked and photographed
Chimney sweep logs do not sweep chimneys. They loosen some creosote - which then falls where a brush and vacuum still have to collect it.
Famco Damper Repair: The Brooklyn Owner’s Guide
We keep Famco damper repair parts on the truck and in stock here in Brooklyn, including replacement cable assemblies, blade sets, and mounting frames for most Famco top-mount and throat-mount models. A typical Famco damper repair runs $220 to $480 installed, depending on whether we’re replacing a cable, a blade, or the whole assembly. Most jobs are finished the same visit. The way people usually find us is simple: the damper stops closing all the way, the handle spins but nothing happens, or cold air pours down the flue in January no matter how hard they crank it shut.
We’ve been working chimneys across Brooklyn since 1999, long enough to know that Famco dampers are good hardware that eventually meets a hard fight: New York weather. Wendell Pike and his crew have pulled failed Famco units out of brownstones off Flatbush Avenue and row houses in Carroll Gardens, and the failure pattern is almost always the same. It’s rarely the whole damper. It’s one part that gave up.
Which Famco Models This Applies To
Famco makes two lines you’ll most often find in Brooklyn homes: the LD series (top-mount, cable-operated) and the older RD series (throat-mount with a lever or chain pull). The LD series is the one we see in most modern installations: a spring-loaded butterfly blade sitting at the top of the flue, opened and closed by a stainless cable that runs down to a handle bracket near the firebox. The RD series sits lower, right in the throat, and uses either a key-lock plate or a lever assembly. Parts do not swap between the LD and RD lines; the blade diameters, spring tension, and cable mounting are all built to different specs.
Here’s the compatibility gotcha we run into constantly: Famco dampers are sized to the flue’s inside diameter, not the chimney’s outside measurement or the brick opening. An 8-inch Famco damper fits an 8-inch inside flue diameter, which often means a 13×13 exterior flue tile. We measure the flue with a ladder and a tape before we quote a part, because a damper that’s even a half-inch off will bind, let air leak around the blade, or snap the cable under tension. The model number is stamped on a metal tag on the frame or on the underside of the blade; if it’s corroded away, we match it by diameter. When the OEM Famco part is discontinued or backordered – which happens more often than we’d like with RD-series components – we use quality aftermarket equivalents from the same spec range. If we wouldn’t install it on a chimney in our own neighborhood, it doesn’t go on the truck.
One more thing worth knowing: Top Hat Chimney is an independent service provider. We install and repair Famco products, and we also stock parts for DuraFlex, HeatShield, and Gelco systems. We’re not affiliated with the manufacturer, which means we tell you plainly when a part is worth replacing and when the whole damper needs to go.
Signs Your Famco Damper Repair Is Failing
- The handle turns freely but the damper doesn’t move. This is the most common failure on LD-series cable dampers. The cable has either snapped inside the conduit or stripped at the handle set screw. The damper blade is usually fine; the cable is the cheap part that broke.
- Cold air drops down the flue even when the damper is shut. On top-mount Fincos, the blade isn’t seating flush against its frame. This is often rust build-up or a spring that’s lost tension over years of heat cycling. On RD-series throat dampers, the cast frame can warp and never close tight again.
- You feel resistance partway through the pull, then a popping release. That’s the cable jumping off its pulley or the blade hinge binding. If you keep pulling, you’ll eventually snap the cable or bend the blade, which turns a $40 cable job into a full assembly replacement.
- Visible rust flakes or condensation streaks near the firebox. A damper that doesn’t seal lets warm indoor air rise all winter, and when it hits the cold flue you get condensation. In Brooklyn’s freeze-thaw winters, that moisture works its way into the mortar and makes everything worse over time.
- You hear a metallic rattle on windy nights. That’s the blade moving against a weakened spring. It’s not going to fix itself, and the next hard nor’easter can bend the blade out of alignment.
Replacement Cost & What’s Included
In Brooklyn, you’re looking at these installed ranges for Famco damper work:
- Cable replacement only: $170 to $260. Parts, new hardware, and a full sweep of flue-tension calibration included.
- Blade and hinge rebuild: $240 to $380. We replace the blade and hinge pins, remove rust, and realign the seating surface.
- Full damper assembly replacement: $380 to $560. New Famco-compatible damper, new cable, new mounting frame. Common when the frame itself has warped or corroded.
- Labor-add for rooftop access above three stories: Brooklyn brownsteps are the driver here. Four stories and up with a steep roof pitch adds $60 to $120 for staging and safety setup.
What drives the range is flue access. A second-story chimney with a ladder has a different labor profile than a four-story brownstep where Wendell’s crew is up on a ridge line with a harness. Every quote is fixed before we start. The number you hear on the phone is the number on the invoice. Every repair carries our 90-Day Done Right Promise: if it’s not right, one call brings the crew back at no additional cost. That promise applies to the damper repair, the installation, and the parts we supply.
DIY or Call Us?
We’ll be straight with you: some things on a chimney are fine to check yourself, and some are not. What you can safely do is confirm the damper is actually the problem: with the fireplace cold, shine a flashlight up the flue and look at the blade position. If it’s stuck half-open, note that. If the handle spins free without any resistance, note that too. That info saves us time when we arrive, and it helps us bring the right parts on the first trip.
What you should not do is climb onto a Brooklyn roof to pull a Famco unit yourself. Top-mount dampers get installed at the top of a flue for a reason: the cable runs through the full flue length under tension, and removing the unit means detaching hardware at height, often on a pitched or parapet-walled roof. We’ve seen one too many roof edges in Crown Heights and Bay Ridge where a homeowner’s ladder only reaches up so far. Add in the spring-loaded blade, masonry edges, and a two-story fall, and it’s just not worth it. Let us know what you found, and call (516) 289-9316. If it doesn’t need doing, we’ll tell you that too.
FAQs
Most Famco dampers in Brooklyn last 10 to 20 years, with the cable being the first thing to fail, usually at 8 to 12 years. The salt air from the harbor and the freeze-thaw cycles that run November through March accelerate rust on the blade and frame. A damper that’s never serviced may still look fine from the firebox and be nearly seized at the top. If yours is past 15 years old and you’re pumping humidity or cold air in, it’s worth having us inspect it before the cable snaps mid-winter. Call (516) 289-9316 and we’ll schedule a look.
About 70 percent of the Famco dampers we see in Brooklyn can be repaired with a cable or blade replacement. The ones that can’t are usually RD-series units where the cast frame has warped or the mounting flanges have rusted through. There’s no point rebuilding a blade when the frame won’t seat. We’ll show you the camera footage so you can see exactly which situation you’ve got, then quote you the repair and the replacement both. Whatever we don’t need to sell you, we won’t.
Most Famco damper repairs take 90 minutes to two and a half hours, start to finish. Cable replacements are on the shorter end; full assembly replacements on a tall Brooklyn brownstone with roof access issues take longer. We’ll give you a real arrival window, and the same crew that picks up the phone is the crew that shows up. Call (516) 289-9316 for a same-week appointment.
We stock Famco LD-series cables, blade springs, hinge pins, and mounting frames on the truck, covering the common 6-inch through 10-inch flue diameters. RD-series parts for older Brooklyn row houses are sometimes a one-or-two-day order from our local supplier. Either way, you’ll know before we set a single tool on the roof. Estimates are free, and there’s no trip charge inside the service county.
Written by Wendell Pike, Owner, Top Hat Chimney at Top Hat Chimney, serving Brooklyn and nearby areas.